The Thorn Thermocouple also known as the thermocoupling, whenever you start the pilot, you have to manually depress the gas valve for 10 to 20 seconds to provide the thermocouple a period of time to heat up and begin generating enough current to keep the gas valve open. If the pilot won't stay lit regardless of how long you depress the gas valve, the thermocouple could possibly be worn out. You can test the thermocouple by disconnecting it from the gas valve and measuring the voltage between your conductors. You should get yourself a reading of around 40 millivolts when the pilot flame is on. A reading of significantly less than 25 millivolts indicating that the thermocouple can be faulty and must be replaced., Main Thermocouples Are Dispatched Same Day, For Next Day Delivery

Delivery

THORN Boiler Spares orders - delivered within 24 hours for all in-stock THORN spare parts, when purchased before 3pm. We also supply many other spare parts and accessories for THORN boilers.

Disclaimers:

  • Warranty

    THORN spare parts come with manufacturers standard twelve months warranty.

  • Warning

    When replacing any spare part on appliances, use only genuine boiler spare parts that you can be assured conform to the safety and performance specification that the boiler manufacturer recommends. For your safety & your families, please do not use reconditioned or copy parts that have not been clearly authorised by the boiler manufacturer.